Troubleshooting, Upkeep and Buying a New System

Glossary of Heating, Cooling and Airflow Terms

Quotes, service notes and equipment labels lean on shorthand: AFUE, line set, static pressure. Knowing the words makes it easier to follow an explanation of what failed and to compare one quote with another.

Find a Term

Type a word or choose a group, then press Show Terms.

AFUE Heating
Annual fuel utilization efficiency: the share of a furnace’s or boiler’s fuel that becomes heat for the house over a season.
Aquastat Heating
The control on a hot-water boiler that reads the water temperature and switches the burner on and off to hold it in range.
BTU Heating
British thermal unit, the basic measure of heat. Furnaces are rated in BTUs per hour of heat made, air conditioners in heat removed.
Circulator Heating
The pump that moves hot water from the boiler out to the radiators, baseboards or floor tubing and back again.
Compressor Cooling
The pump in the outdoor unit that squeezes refrigerant and drives it around the system.
Condensate line and pump Cooling
The drain for water pulled from the air by the indoor coil or a high-efficiency furnace. Where no drain is close, a small pump lifts it out.
Condenser Cooling
The outdoor half of a central air conditioner: the compressor, a fan and a coil that gives off the heat taken from the house.
Damper Airflow
A plate inside a duct, set by hand or by a motor, that sends more air to some rooms and less to others.
Draft inducer Heating
A small fan on a modern furnace that starts before the burners light and pulls their exhaust through the heat exchanger and out the vent.
Ductless head Cooling
The indoor part of a mini-split, mounted high on a wall or in the ceiling, with its own fan, filter and remote control.
Evaporator coil Cooling
The indoor coil, usually on top of the furnace or inside the air handler, where cold refrigerant pulls heat and moisture out of the air.
Expansion tank Heating
A small tank on a hot-water heating system that gives heated water room to expand. Once it fills with water, the pressure climbs.
Flame sensor Heating
A thin rod in the burner flame that tells the furnace the gas has lit. When it is dirty, the burners light and shut off seconds later.
Heat exchanger Heating
The metal chambers that keep the burner flame and its exhaust apart from the air sent to the rooms. A crack can let carbon monoxide through.
Heat pump defrost Heating
In winter a heat pump’s outdoor coil frosts over, so the unit reverses for a few minutes to melt it. A cloud of steam outside is normal.
Hot surface igniter Heating
The part that lights the gas on many newer furnaces: a small element that glows orange-hot. It is brittle and wears out with use.
HSPF2 Heating
Heating seasonal performance factor under the newer test standard: the heat a heat pump gives over a winter per unit of electricity.
Limit switch Heating
A safety switch that shuts off a furnace’s burners when it overheats, often because a clogged filter or closed registers are starving it of air.
Line set Cooling
The pair of copper pipes, one of them insulated, that carries refrigerant between the indoor and outdoor units.
MERV Airflow
Minimum efficiency reporting value, a scale from 1 to 16 for how much a filter catches. Higher numbers trap finer dust but can restrict the airflow.
Plenum Airflow
The box on the furnace or air handler where the main ducts begin: the supply plenum sends air out, the return plenum brings it back.
Refrigerant Cooling
The fluid that carries heat out of the house. Older systems use R-22, no longer made or imported in the U.S.; newer refrigerants cannot be mixed with it.
Return air Airflow
Air drawn back to the furnace or air handler through return grilles. Too few returns leave rooms stuffy and make the blower strain.
SEER2 Cooling
Seasonal energy efficiency ratio under the newer test standard: the cooling an air conditioner or heat pump gives over a summer per unit of electricity.
Short cycling Airflow
A system that switches on and off every few minutes without finishing a normal run, often from oversizing, a clogged filter or overheating.
Static pressure Airflow
The resistance the blower pushes against in the filter, coil and ducts. A technician measures it to find restrictions such as undersized ducts.
Steam vent Heating
The small valve on a steam radiator that lets air out so steam can fill it, then closes. A stuck vent leaves the radiator cold.
Supply register Airflow
The grille where heated or cooled air enters a room. Closing many registers at once can upset the airflow through the whole system.
Ton Cooling
A measure of cooling capacity, not weight: one ton removes 12,000 BTUs of heat an hour.
Zoning Airflow
Dividing a house into areas with their own thermostats, so motorized dampers or separate units can heat or cool each one on its own.